Photometry
Control systems
Intelligent luminaire drivers can be programmed with complex dimming profiles. Up to five combinations of time intervals and light levels are possible. This feature does not require any extra wiring.
The period between switching on and switching off is used to activate the preset dimming profile. The customised dimming system generates maximum energy savings while respecting the required lighting levels and uniformity throughout the night.
As an option, the LensoFlex®2 and LensoFlex®4 modules can be equipped with a Back Light control system.
This additional feature minimises light spill from the back of the luminaire to avoid intrusive light towards buildings.
Custom dimming profileBack Light control
LensoFlex®2 LensoFlex®2 is based upon the addition principle of photometric distribution. Each LED is associated with a specific PMMA lens that generates the complete photometric distribution of the luminaire. The number of LEDs in combination with the driving current determines the intensity level of the light distribution.
A
LM
B
100 %
80 %
60%
17 21 23 01 03 05 07
40 %
20 %
A B
A. Without Back Light control | B. With Back Light control A. Dimming level | B. Time