Multimeters
Te st
& M
ea su
re m
en t
E q
ui p
m en
t
10850
Compact true-rms meter for commercial applications. The Fluke 117 is the ideal meter for demanding environments like commercial buildings, hospitals and schools. VoltAlert™ technology for non-contact voltage detection. AutoVolt automatic ac/dc voltage selection. Low input impedance: helps prevent false readings due to ghost voltage. Large white LED backlight to work in poorly lit areas. True-rms for accurate measurements on non-linear loads. Measures 10 A (20 A overload for 30-seconds). Resistance, continuity, frequency and capacitance. Min/Max/Average with elapsed time to record signal fl uctuations. CAT III 600 V safety rated. Model includes the following: 4 mm silicone test lead set Use for Dc Millivolts, DC Volts, Auto Volts, AC millivolts true-rms, AC volts-rms, Continuity, Ohms, Diode Test, Capacitance, LoZ Capacitance, Hz(V or A input), AC amps true-rms (45Hz to 500Hz), Volt Alert (Non Contact Volt warning)
Order Code
C3972577
AC Current Range 0.01 A to 10 A
AC Voltage Range 0.1 mV to 600 V
Basic DC Accuracy 0.005
Battery Running Time 9 volt Alkaline 400 hours typical
Capacitance Range 1nF - 10000ÁF
DC Current Range 1 mA to 10 A
DC Voltage Range 0.1 mV to 600 V
Dimensions H x W x D 167 mm x 84 mm x 46 mm
Display Counts 6000
Frequency Range 0.01Hz - 50KHz
10826
True RMS AC voltage and current readings, 6000 count resolution, min-max average recording, as well as frequency and capacitance ranges. Despite all of these and many other useful features, the 170 Series remains easy to use. The ergonomic case with intergrated holster protects the units in rough and tough environments. To change the batteries, the case does not have to be opened as access to the batteries is through an easy to open battery door. All outputs are protected to EN61010-1 CAT IV 600V/CAT 111 1000V. The Fluke 170 Series is supplied with TL75 test leads, installed 9V battery and user manual and comes with Fluke s unique lifetime warranty.
Features: True-RMS measurments Digital display counts, updates 4 times per second Display backlight Analogue bargraph/segments, updates 40 times per second Auto and manual ranging Display hold and auto hold Min-max-average recording mode with min/max alert Temperature readings (bead thermocouple probe included) Smoothing mode allows fi ltering of rapidly changing inputs Audible continuity and diode test Test lead alert warns for connection of test leads Unsafe voltage alert warns for voltages above 30V Low battery indication Ergonomic case with intergrated holster Easy battery exchange without opening the complete case Selectable sleep mode preserves battery life Warranty
Order Code
C3945686
AC Current Range 0.01 mA to 10 A
AC Voltage Range 0.1 mV to 1000 V
Basic DC Accuracy 0.0015
Battery Running Time Alkaline, 200hrs typical
Capacitance Range 1nF - 10000ÁF
DC Current Range 0.01 mA to 10 A
DC Voltage Range 0.1 mV to 1000 V
Dimensions H x W x D 190 mm x 85 mm x 45 mm
Display Counts 6000
Frequency Range 0.01Hz - 100KHz
Fluke 117- Electricians, Commercial & non contact multimeter 175 multimeter