Scopes

125 Scopemeter

A multimeter measurement just doesn t give enough detail to determine the cause of a fault. Signal anomalies, dropouts and glitches that might cause a machine to go down, are best displayed with an oscilloscope. The ScopeMeter 125 Series simultaneously measures and checks waveforms. The unique Connect-and-View™ triggering automatically displays stable waveforms of virtually any signal. Dual-input 40 MHz or 20 MHz digital oscilloscope. Two 5,000 counts true-RMS digital multimeters. Automatic measurements.

A dual-input TrendPlot™ recorder. Connect-and-View™ trigger simplicity for hands-off operation. Shielded test leads for oscilloscope, resistance and continuity measurements. 10:1 Voltage Probe included for high frequency measurements. Up to 7 hours battery operation. 600 V CAT III safety certifi ed. Optically-isolated interface for PC connection. Fluke 125 gives bus health and power measurements.

Specifi cations Oscilloscope Bandwidth: 40 MHz Dual input True RMS Meter: Vdc, Vac, Vac+Vdc, Ohms,Continuity , Diode-test, Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset TrendPlot Recording: Automatic vertical scaling and time compression. Display the actual, MIN, MAX and AVG reading. Cursors: ΔT, 1/ΔT, V, ΔV, rise- and fall time Real-time sample rate: 25 MS/s Equivalent sampling rate: up to 2.5 GS/s (125, 124) or 1.25 GS/s (123). Inputs and digitizers:2 Timebase range: 20 ns - 1 min/div Input sensitivity: 5 mV - 500 V/div Trigger types: Connect-and-View™, Free Run, Single Shot, Edge, Video, External Glitch capture: 40 ns Scope measurements systems Automatic measurements: 26 (all instruments) On top, Fluke 125 has additional measurement functions for Power (W), VA, VAR and Power Factor (PF) for single phase and balanced-three-phase (delta) power systems. Harmonics mode: Fluke 125 has capability to analyze the harmonics contents of power signals. See below for details. Maximum record length: 512 min/max pts per input Memory: 20 screens and setups RS232/USB Interface: Optically isolated via optional PM9080 or OC4USB for interfacing to Printer or PC Additional Power measurement capabilities Measurement types: Watt,VA,VAR,Power Factor (PF) Power confi guration: Single phase or balanced three-phase (delta- confi guration) mains supply Voltage measurement: Channel A; using STL120, voltage probe or direct input Current measurement: Channel B, using i400s (included) or other compatible current clamp Current Clamp or Shunt sensitivity: 0.1 / 1 / 10 / 100 / 1000 mV/A, 10 mV/ mA and 400 mV/A. Harmonics Mode Converts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic Analyzed waveform: Voltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated. Harmonics Frequency range: DC up to 33rd harmonic (for fundamental up to 60 Hz); DC up to 24th harmonic (for fundamental up to 400 Hz). Display: Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental Measurements: Relative amplitude of individual harmonics; THD in %r or %f. Environmental Specifi cations Operating Temperature: 0 ºC to 50 ºC Storage Temperature: -20 °C to +60 °C Operating Altitude: 3,000 m

10841

Order Code

C3955685

336