Nominal flux (lm)
(*)
Power consumption
(W)
Nominal efficacy (lm/W)
Luminaire output flux
(lm)
Luminaire efficacy (lm/W)
T8 equivalent
(W)
Luminaire Current (mA)
Line Current
(A) Typical Typical Typical Typical Typical Typical
V LN
L E D
S ta
nd ar
d ve
rs io
n 300 0.13 4880 30 163 4441 148 2*36
325 0.2 7760 46 169 7062 154 2*58
V LN
L E D
E m
e rg
e n cy
Ve
rs io
n 300 0.13 4880 /
810 (EM) 30 163 4441 148 2*36
325 0.2 7760 / 810 (EM) 46 169 7062 154 2*58
V LN
L E D
E xp
lo si
o n P
ro o f
Z 2 1/
2 2
300 0.13 4880 / 810 (EM) 30 163 4441 148 2*36
Z 2 1/
2 2
325 0.2 7760 / 810 (EM) 46 169 7062 154 2*58
Z2 700 0.2 6500 46 142 5915 128 2*58
Performance
Tolerance on LED flux is ± 7% and on total luminaire power ± 5% (*) The nominal flux is an indicative LED flux @ Ts 85°C based on LED manufacturer s data. The real flux output of the luminaire depends on environmental conditions (e.g. temperature and pollution) and the optical efficiency of luminaire. The type of LED used is subject to change due to the ongoing rapid progress taking place in LED technology.
Ordering Information
ID Watt LED Colour Surge Protection Switching/dimming control Other options / accessories
VL N
L ED
30 46
N Neutral white
(4000K) W
Warm white (3000K)
1 10kV
DALI DALI Dim
E1 Emergency version - 1 hour
Z2 Zone 2 Z21/22
Zone 21/22 TW
Through-wire (2 x gland)
Example:
VLN LED46 N1 DALITWZ21/22
437